Ideas.  Interesting.  Public catering.  Production.  Management.  Agriculture

Computer socket rj 45 double length width. Step-by-step instructions for installing a double socket. Internet cable connection diagram by color

In many families, several devices connect to the Internet: without world wide web We don’t even imagine life, that’s why everyone needs their own line. They work mainly using a wireless protocol - Wi-Fi, but there is still a wire, since wired Internet is still more stable than wireless. During repairs, all wires are hidden in the walls and “Internet” wires are no exception. They, like electric ones, are plugged into sockets, only of a different standard: they are called computer or information. They can have different connectors, but the most common is RJ 45. You can do the installation and connection yourself, but since the connector looks unusual in appearance, there are more than two or three wires in it, and the connection is not ensured by soldering or twisting, you need to know , how to connect an Internet outlet and also the connector that should be inserted into it.

RJ-45 connector crimping

The Internet cable entering an apartment or house, most often called twisted pair, often ends in a small plastic connector. This plastic device is a connector, usually RJ45. In professional jargon they are also called “Jack”.

Its body is transparent, so wires of different colors are visible. The same devices are used on connecting wires that connect computers to each other or to a modem. Only the order of arrangement (or, as computer scientists say, pinout) of the wires can differ. The same connector is inserted into a computer socket. If you understand how the wires are distributed in the connector, there will be no problems connecting the Internet outlet.

Internet cable connection diagram by color

There are two connection schemes: T568A and T568B. The first option - “A” is practically not used in our country, and everywhere the wires are arranged according to the “B” scheme. It is necessary to remember it, since it is what is required in most cases.

To finally clarify all the issues, let's talk about the number of wires in a twisted pair. This Internet cable comes in 2-pair and 4-pair versions. To transfer data at speeds up to 1 Gb/s, 2-pair cables are used, from 1 to 10 Gb/s - 4-pair. Today, apartments and private houses are mostly supplied with flows of up to 100 Mb/s. But with the current pace of development of Internet technology, it is quite possible that in just a couple of years the speeds will be measured in Megabits. It is for this reason that it is better to immediately expand a network of eight rather than 4 conductors. Then when changing speed you won't have to redo anything. The equipment will simply use more conductors. The difference in cable price is small, and sockets and connectors for the Internet still use eight-pin ones.

If the network is already wired in two pairs, use the same connectors, only after the first three conductors laid according to scheme B, skip two contacts and place the green conductor in place of the sixth (see photo).

Crimping a twisted pair cable into a connector

There are special pliers for crimping wires in the connector. They cost about $6-10 depending on the manufacturer. They are more convenient to work with, although you can get by with a regular screwdriver and wire cutters.

First, the insulation is removed from the twisted pair. It is removed at a distance of 7-8 cm from the end of the cable. Underneath there are four pairs of conductors of different colors, twisted in twos. Sometimes there is also a thin shielding wire; we just bend it to the side - we don’t need it. We untwist the pairs, align the wires, spreading them in different directions. Then fold according to pattern “B”.

The procedure for sealing the RJ-45 connector in the connector

We clamp the wires in the required order between the thumb and forefinger. We lay out the wires evenly, tightly to each other. Having aligned everything, we take wire cutters and cut off the excess length of the wires laid out in order: 10-12 mm should remain. If you attach the connector as in the photo, the insulation of the twisted pair should begin above the latch.

We insert the twisted pair with the cut wires into the connector. Please note that you need to take it with the latch (protrusion on the lid) down.

Each conductor must get into a special path. Insert the wires all the way - they should reach the edge of the connector. Holding the cable at the edge of the connector, insert it into the pliers. The handles of the pliers are brought together smoothly. If the body has become normal, no special effort is required. If you feel that it “doesn’t work”, double-check whether the RJ45 is installed correctly in the socket. If everything is fine, try again.

When pressed, the protrusions present in the pliers will move the conductors to the microknives, which will cut through the protective sheath and ensure contact.

This connection is reliable and problems rarely arise with it. And if something happens, it’s easy to re-terminate the cable: cut it off and repeat the process with another “jack”.

Video tutorial: crimping an RJ-45 connector with pliers and a screwdriver

The procedure is simple and easy to repeat. Perhaps it will be easier for you to do everything after the video. It shows how to work with pliers, as well as how to do without them, and do everything with a regular straight screwdriver.

How to connect an internet cable to a power outlet

Now we come directly to how to connect the Internet outlet. Let's start with the varieties. Like regular electrical sockets, information sockets come in two modifications:


According to the number of connection points, there are single and double computer sockets.

Although computer sockets differ in appearance, the principle of connecting conductors is the same. There are special contacts equipped with microknives. The protective sheath is cut through the inserted conductor. As a result, the metal of the microknife contacts fits tightly to the metal of the conductor.

How to connect a computer wall socket

Inside each outlet there is a hint on how to place the wires when connecting the Internet cable. Manufacturers stick on the color scheme that we saw when crimping the connector. There are also two options - “A” and “B”, and we also use option “B”.

The case is mounted on the wall, usually with the cable inlet up and the computer connector down. The next steps are simple:


Connecting a twisted pair cable to an outlet is really a simple procedure. Even the first time it will take a few minutes. You can see again what they do and how in the video. It first shows the connection of an Internet cable with 4 wires, then with 8.

How to connect an internal Internet socket

We won’t describe the installation of the plastic box - that’s a different topic. Let's look at the features of connection and assembly. The main problem here is how to disassemble computer sockets. When connecting conductors to them, you need to get to the contact part: a small ceramic or plastic case with built-in microknife contacts. The conductors are connected to this mounting plate, and then the housing is reassembled. And the whole problem is that different manufacturers assemble/disassemble them differently.

For example, from the popular manufacturer of computer sockets Legrand (LeGrand), in order to get to the connectors in the Legrand Valena RJ45 computer socket, you need to remove the front cover. Under it you will find a white plastic impeller (as in the photo), with an arrow on it.

You need to turn the impeller in the direction of the arrow, after which you will have the housing and the contact plate in your hands. It has color-coded conductors. The connection is no different, except that first you need to thread a twisted pair into the hole on the plate, and then separate the wires.

For clarity, watch the video.

Another popular manufacturer of such equipment is Lezard. His system is different. The front panel and metal frame are fixed with small bolts. They are easy to unscrew, but the internal contact plate is held in place by clamps. When assembling and disassembling Lezard computer sockets in the right places, you need to press out the contacts with a screwdriver.

To remove the plastic contact group from the housing, you need to press the latch located on the top. After which you will have a small box in your hands. But that's not all. It is necessary to remove the plastic cover that covers and presses the conductors. Remove it by prying up the side petals with a screwdriver. The plastic is elastic and the effort required is quite decent. Just don't overdo it: it's still plastic. After that, the wiring is standard: according to the markings on the sides (do not forget that we are using diagram “B”).

If you know how to connect an Internet outlet, it’s not difficult to figure out even an unfamiliar model. And now you can upgrade your network yourself (increase the length of the twisted pair, move the computer to another location, make another connection point, etc.), without involving specialists. One more question remains: how to connect double sockets. Two cables are connected to them and then the color scheme is added. This is possible when your network is formed by a modem or two Internet lines are connected. Is it possible to connect both inputs with one cable? It’s possible, but you need to avoid getting confused in the color designation of the wires in the further wiring of the network (remember which color you used instead of which).

Most often, the installation and connection of an Internet outlet related to low-current lines is carried out in a triple block:

  • regular 220 Volt
  • internet socket
  • television under TV

For most models, for example from Schneider Electric (Unica series), Legrand, Lezard, the installation principle is almost the same and does not contain fundamental differences.

Let's take a step-by-step look at the entire cycle of connecting an Internet outlet.

Internet cable

Installation begins with installing the router in a low-current switchboard and connecting it to a 220V power outlet.

Next, a 4-pair UTP series 5E cable is laid in a separate cable channel or groove not connected to power lines.

This cable provides connection speeds of up to 1 Gigabit per second over a distance of up to 100m. Here it is specifications:

There are shielded and unshielded varieties. Foil acts as a shield in networks where there is normal grounding.

One such 5E cable (4 pairs) can only connect two sockets. In this case, 2 pairs will be involved separately.

Installation is carried out with a single wire directly from the switchboard to the socket box. Lead the cable into the installation box and leave the necessary margin - from 15 cm or more.

Installation of an internet outlet

First remove the cover from the socket and pull out the caliper for ease of installation.

If the design of the socket allows, the frame can be mounted initially on the socket box. Thanks to the grooves in the frame, you can easily adjust its horizontal position.

Use 3*25mm screws to pre-tighten the entire structure. At the same time, you check the accuracy of the installation with a Pocket Electric level and tighten the screws completely.

Manufacturers in Lately They began to make frames from aluminum alloy; they are, of course, stronger in design, but at the same time they will not be magnetic to the level. You will have to support it with one hand.

Next, bite off and leave a supply of wire in the socket, a maximum length of 15 cm. Remove the top layer of insulation from the UTP cable.

To remove the insulation, so as not to damage the conductors, it is better to use a special tool - a stripper. But you can do all this carefully and with an ordinary stationery knife.

The top layer of the cable must be cleared to a length of no more than 2.5 cm. Cut off the excess thread in this case that goes between the cores.

A strong thread in twisted pair cables, often used to facilitate opening the sheath over long lengths. It’s even called that – a breaking thread. In telephone cables, it separates bundles and layers.

Lightly unravel the veins individually. Next, pull out the inner part of the socket with the contacts.

As a rule, any brand, be it a TV, an Internet outlet or a regular 220 Volt, should come with instructions.

Instructions for the Schneider Electric Unica internet socket –
Instructions for Legrand –

Standards and connection diagram

Open the cover of the contact part and carefully study the markings. Each RJ45 socket can be connected in two ways:

  • according to standard “A”
  • according to standard “B”

In most cases, the second option is used - "B". To understand where to connect which wires, carefully inspect the housing. It should indicate which standard corresponds to certain contacts.

For example on Unica:

  • protocol “B” refers to the top color coding. When connecting, you will be guided by these colors.
  • “A” – to the bottom color marking

If you figure this out, then there will be no difficulties with further installation. Protocol “B” follows the color scheme according to the EIA/TIA-568B standard. One side of the clip should have the following colors:

  • white- orange
  • orange
  • white- green
  • green

On the other side:

  • blue
  • white- blue
  • white- brown
  • brown

Pass the wire through the cap. In this case, as mentioned above, the top layer of UTP cable insulation should not be removed by more than 2.5 cm.

You cannot strip it right up to the wall of the socket box, as is done with conventional NYM or VVGnG cables.

The section without insulation must be of a minimum length. All these twists are not done easily. Their exact quantity per 1 meter of cable is strictly calculated and regulated.

Otherwise, if you connect and strip it incorrectly, not only the speed, but also the quality of data transfer may decrease.

Next, insert all the wires into the contact grooves by color.

Then you simply snap the lid on. Extra sections of cores that protrude outwards You need to cut it off after closing the lid.

The outlet is actually already connected. All that remains is to insert it into place in the caliper.

The main advantage of such Internet sockets is that with them there is no need to remove the insulation from the cores and expose it to copper. Special knives are already installed inside the socket itself.

When you close the lid, the blades automatically cut through the insulation and create a contact connection. The instructions for such brands often indicate that when connecting the wire, the use of special crimpers is prohibited.

It’s as if it’s already in the design. That is, when the lid is closed, it itself cuts off the insulation and lays the wires to the required depth of the connector.

Connecting to the router and crimping the connector

After installing the Internet outlet itself, all that remains is to correctly connect the cable to the router in the communication panel.

Remove the insulation from the other end of the cable by 2-3cm. The wires are fluffed up and inserted in a certain order, according to the TIA-568B standard, or simply “B”.

The arrangement of colors is considered from left to right:

  • white- orange
  • orange
  • white- green
  • blue
  • white- blue
  • green
  • white- brown
  • brown

Standard "A" is sometimes used if you need to connect one computer to another. Here you crimp one end of the cable according to standard “B”, and the other according to “A”. In general, if both ends of the cable are crimped to the same standard (AA or BB), then this is called a patch cord. And if they are swapped (AB or BA), then it is a cross.

Again, there is no need to strip the veins. Just insert them into the connector until it stops.

After which all this is pressed in with a special crimper. Some people do this with a thin screwdriver or a knife blade, although this can easily damage the connector.

The cat5E and cat6 cables in the RJ45 connector are crimped according to the same principle. Another "fork" is not required here. Cables differ in data transfer speed; cat6 has a higher speed.

Checking your Internet connection

After installing the Internet socket and connector at the other end of the cable, it is advisable to check the connection and integrity of all connections. This can be done with the cheapest Chinese device.

What is its essence? There is a signal generator that sends pulses according to certain codes, and a receiver. The generator is connected to the location where the router is installed, and the receiver is connected directly to the outlet itself.

After the pulses are applied, the signals are compared. If everything is in order, the green LED lights on the receiver body light up one by one. If there is a break or short circuit somewhere, then one or more light bulbs will not light up at all.

When this happens, the first thing to blame is poor contact in the connectors. Most often, it is there, on any core, that the insulation is not completely cut off and, accordingly, there will be no connection.

At the very end, a ready-made, tested cable with a connector is connected to the router.

A complete set of all tools for cutting, crimping, internet connections utp cable You can order on AliExpress (free delivery).

How to connect a 4-wire telephone cable

But what should you do if you use a 4-wire telephone cable for the Internet, and the socket is a standard 8-wire socket? How to connect the circuit in this case?

Simple color matching won't help here. That is, if you insert the white-blue core into contact with the white-blue marking and connect all the other wires in the same color, there will be no signal.

This is explained by the fact that to transmit the signal you need to use contacts 1-2-3-6.

On one side, connect two wires to contacts 1-2:

green = blue lived


In this case, everything should work without problems. Just remember that here the most important thing is not the colors, but the positions. Colors are used to make it visually easier to distinguish the positions of the same core at different ends of the cable.

Also keep in mind that when using 4 wires, i.e. two pairs of twisted pair, you can achieve speeds of up to 100Mbps. But for a gigabit network (1Gbit/sec) you will already need all 8 wires.

Errors when connecting an Internet outlet

1 Incorrect connection of cores according to the protocol.

You can easily confuse the order of the wires on the connector and in the socket itself. Roughly speaking, turn them 180 degrees.

Here everything is checked by a more careful study of the inscriptions on the body of the socket and the color of the wires themselves. A tester with a signal generator and receiver is a good helper for identifying such errors.

If the wires are connected incorrectly, the lights on the tester will light up not in order from 1 to 8, but in random patterns. For example, first 1, then immediately 3, then 2, etc.

2 It is not significant, but still considered an error if the cores from the contact plates of the socket are cut off not after closing the cover, but before this moment.

That is, immediately after placing them in their places in the slot. In this case, the core may accidentally fall out, and it will not be possible to insert it back after being cut. You will have to clean everything out again and go through the entire connection cycle again.

And if you left the supply of cable in the installation box small, then you will face a big headache.

3 Stripping external insulation over a long distance, right up to the walls of the socket box, as in conventional 220V networks.

As mentioned earlier, the result here is a deterioration in the speed and quality of the signal. Moreover, there is no need to first unravel the twisted pairs to the point where the insulation is cut, especially with a screwdriver. Just embroider them by spreading the veins apart required length to insert into the slots.

According to the standard, it is not allowed to unwind a twisted pair cable by more than 13mm, otherwise crosstalk errors will appear in frequency response tests. In practice, problems will begin when the network is loaded with traffic.

The rj-45 socket is called a computer socket because it is usually used to connect to the Internet. A double rj-45 socket is used if you need to connect one computer to the Internet and a telephone to the city network in the same room. The same double rj-45 is installed if the computer needs to be connected to the Internet and local network, in offices this happens even more often than in residential apartments. Be that as it may, you can connect a double socket yourself; this does not require special preparation, just read the detailed instructions.

First of all, you need to decide whether you will need an internal or external (overlay) connector. The internal one is installed using an additional distributor and allows you to hide the wiring behind a special partition or decorative element. This allows you to keep the wires out of sight and further protect the socket box from possible influences. But additional work will be required on the wall, and when moving a computer or phone to another place, you will have to start all over again.

It is easier to use and install an external or overhead socket rj-45. It is usually used everywhere, excluding places with high humidity or dust (in this case, the contacts may oxidize or become dirty, which will lead to signal blockage). Socket boxes can also be different. Double socket boxes can be one-sided or pass-through. Single-sided is used if one direct connection is intended. A walk-through socket box will be needed where the network will be connected from several rooms.

If you do not resort to the help of a specialist, but install the rj-45 with grounding yourself, you need to prepare some materials and tools in advance. You will need to purchase:

  • perforator;
  • screwdrivers;
  • pliers;
  • sharp knife for stripping wires;
  • double socket rj-45;
  • a tool that can be used to crimp a wire into a connector.

It would be nice to have a cable tester so that you can make sure that everything is going correctly while you work. But you can do without it by simply checking the connection after completing all the work: if the network does not work, then you will have to go back and reconsider the connection of the wires according to the diagram.

Video “Connecting an outlet - the process in detail”

Preparation

If you decide to hide the socket in the wall, then you need to install a socket box in it. To do this you will need a hammer drill and a special crown. With their help, a corresponding hole is hollowed out in the wall, then it is cleaned of debris and dust. After this, the socket itself is installed and secured with alabaster.
If an overhead system is being installed, then the box must be disassembled, the module removed from it, and the socket box attached to the wall (or floor) with screws.

In some cases, grounded computer outlets are required. If the grounding cord is not installed separately, you need to purchase a rj-45 socket model already with grounding (they are somewhat more expensive, but this is computer safety).

Installation

The difference between a computer socket and all others is the use of 8 copper wires, twisted in pairs. These 4 pairs are called twisted pairs, and installation consists of connecting them correctly. First, the terminal block needs to be disconnected from the main mechanism. This is done by carefully turning the white lock clockwise. Now you need to run the cable through the back.

Installation of walk-through sockets, like regular sockets, is carried out according to one of two schemes: T568B or T568A. Today, network devices themselves can recognize the scheme and even adjust if necessary, but more often they use scheme B, in which the operation of the port is ensured by a green and orange pair of contacts. The cross-connection diagram is usually present on the terminal block body; according to this diagram, you need to connect the twisted pairs. In order not to confuse anything, you need to look at the color markings very carefully. The grooves of the cover correspond to the twisted pair wires in color: white-brown corresponds to brown, white-blue corresponds to blue, and so on.

It is necessary to very carefully remove the insulation from the cable (no more than 3 cm), unravel the wires (no more than 1.5 cm) and strip them. Now it’s time to insert the twisted pair wires into the grooves of the cover in accordance with their color markings. If you use a legrand rj-45 socket (preferably with grounding), then you will not have to strip the ends of the wires. It has such a convenient design that the wires can be inserted tightly into the corresponding grooves, and the contact pads themselves will secure them when the cover is lowered. The fact is that each pad is a pointed plate; when the lid is lowered, the plate cuts through the insulation of the conductors just enough that they touch the signal-conducting cores of the conductors.

The connection of one socket has been completed; now the terminal block needs to be returned to its place at the back of the socket and the latch must be closed. To do this, the latch is turned counterclockwise. It would be good to check if everything works. If you don't have a cable tester, you'll have to connect something, like a modem, and make sure it works. If the modem does not turn on, you will have to check once again whether the wires are installed correctly and connected according to the diagram.

Now you need to do the same thing to connect the wires to the second outlet. Once you are sure that both outlets are working, you can close them. If both wires are correctly and conveniently placed in the box, you can close the socket, completely hiding the socket box, and install a decorative frame. The external socket just needs to be fixed to the surface, the main thing is that the socket box is installed firmly. This will ensure that the entire device remains stationary during operation. The interior remains to be hidden using wallpaper, panels or special decor. The double rj-45 socket is installed and ready for use, the main thing is not to forget about grounding, since safety depends on it. In addition, some companies refuse to accept equipment for warranty repair if it was operated without grounding.

Despite the rapid development of wireless communications, RJ-45 sockets are still required elements of a structured cabling system modern building. We suggest considering their structure, types, pinout options and installation methods. The apparent simplicity of the question can be misleading, since there are certain nuances that need to be paid attention to.

Design features

Despite the variety of types of twisted pair sockets, their design is almost identical, with the exception of small details. As an example, let's look at a typical external single-port device.

Rice. 1. Basic elements of an external RJ-45 socket

Designations:

  • A – plastic cover.
  • B – base.
  • C – functional board with a standard connector installed on it.
  • D – convectors for connecting twisted pair cables.
  • E – tie for fixing the cable.
  • F – connector for connector.

Externally, the socket resembles an RJ-11 telephone standard; the main difference is the number of connector pins, there are eight of them, not four. Accordingly, a computer socket can be used as a telephone socket, but not vice versa.

U various types devices may have minor characteristic features, but in general the design concept remains unchanged.

Types and characteristics

The main parameters of these switching devices are determined by the following criteria:

  1. Number of ports.
  2. Category.
  3. Execution.

Let's briefly talk about each of them.

More doesn't mean better.

One of the main parameters is the number of ports. As a rule, there can be from one to four. If you need to use a larger number of connections, it is easier to install a patch panel, but such a need indicates an ill-conceived network layout. In addition, it should be taken into account that a large number of patch cords connected nearby causes some inconvenience.


Rice. 2. Krauler 4-port external socket

In practice, when organizing an office or home LAN, one and two-unit modules are mainly used.

This parameter is directly related to the characteristics of the cable used for installation computer network. It's about about bandwidth, which determines both the data transfer speed and the ability to use special network technologies. Below is a table that shows the relationship between category and bandwidth.


Currently, when installing a LAN, cables with a category lower than 5e are practically not used.

Execution.

The method of mounting the switching device depends on this parameter. There are two versions:

  • for external (external) installation (such sockets are shown in Figures 1 and 2);
  • for indoor installation.

Internal two-port RJ-45 socket disassembled and assembled

As a rule, the choice of one version or another depends on how the LAN wiring is done. If it is external (for example, laid in boxes), external sockets are used. In cases where hidden wiring is done, the internal devices look more aesthetically pleasing.

Separately, it is necessary to highlight the sockets that are installed directly on the box. Technically, such execution can be considered both internal and external.


The technical characteristics of the LAN are not affected by the execution.

Modular designs.

Speaking about performance, we cannot fail to mention modular designs. This solution allows you to assemble a socket in a standard case for a specific combination, for example, install it in RJ-45 and RJ-11 modules or with different categories.


RJ-45 pinout

There should be no problems with this, since opposite each contact group there is a color marking that complies with the T568A and T568B standards (can be marked with the letters “A” and “B”, as in the figure below).


It doesn’t matter which standard is used, the main thing is that it is the same type for the LAN, otherwise problems are guaranteed. It is believed that we have adopted a “crimp” type T568B, but this is a rather conditional statement.

If you do not know which standard your provider uses, then you can install it using the pinout of the connector installed on the cable entering the apartment.


Detailed connection instructions

Let's start with the tool that you will need to seal twisted pair sockets. Ideally, it is advisable to purchase a universal extractor (shown in Figure 9). It allows you to press and cut the rest of the wire in one movement. Thanks to Chinese manufacturers, such a universal tool costs about 3-4 dollars. The price of branded products can be 2-3 times more expensive.


Rice. 9. Universal extractor

This tool has a special mechanism that allows you to press the wire between two contact knives and cut off its excess (3 in Fig. 9). In addition, it is equipped with a flat screwdriver (2) and a hook (1), which allows you to remove the wire if it is incorrectly terminated. The cost of a universal extractor is relatively low, but the benefits are quite tangible.

No less useful are universal insulation stripping pliers. They cost about the same as an extractor and can cut Ø3.5-9 mm cables such as UTP, STP, FTP. It is possible to adjust the depth of the cut.


It is not advisable to use a knife to strip the insulation, since in this case there is a high probability of damaging one of the twisted pair wires.

Having dealt with the necessary tools, let's move on to the algorithm for embedding a twisted pair cable into a switching device. We will assume that the cable has already been laid and the outlet space has been prepared. The procedure is as follows:

  1. Using universal pliers, cut off the outer insulation layer from the end of the wire. It is enough to expose 4-5 centimeters. You need to act carefully so as not to damage the wires. If this happens, trim the damaged area, adjust the depth of the cut and repeat the operation.
  2. After removing the insulation, level each pair. Please note that there is no need to clean them. Each pad contact has special micro knives that cut the insulation and ensure reliable contact and fixation of the wire.
  3. We disassemble the socket. To do this, remove the front panel. To do this, you will need to unscrew the fixing screw or unfasten special latches (depending on the design). If you are using a modular socket, you will need to remove the modules from it.
  4. We fix the cable on the module using a tie (E in Fig. 1) or another method provided by the design.
  5. We insert the wires into the clamps, and it is necessary to adhere to the color markings of the selected standard. Do not try to recess the veins deeply; it is enough to simply fix them with a little force (A Fig. 11).
  6. Using an extractor, we perform pressing (B in Fig. 11).

Rice. 11. A – cable with wires routed to clamps, B – pressed in with an extractor

On at this stage Let's make a small digression regarding the use of improvised means for pressing. Sometimes you can find advice in which, in the absence of the necessary tool For pressing, it is recommended to use a utility knife or a thin slotted screwdriver. This approach can only be used as a last resort, when access to the network is urgently needed, but there is no tool at hand. But in the future, such a socket must be clamped. Otherwise, there is a high probability of losing contact between the wire and the latch after some time.

We also note that many branded manufacturers include a simple plastic extractor for each socket, which allows you to securely seal the wire, after which all that remains is to carefully trim off the excess.

  1. After pressing, the module is installed in place. If the socket is external, then its base is screwed to the prepared area, so that the cable is supplied from above, and the connector is from below. When installing an internal socket, its base is installed in a prepared glass and fixed in it.
  2. We fasten the front panel and then check its functionality. This can be done using a special tester, but it’s easier to connect a computer and check for a network connection. If problems arise, first of all check the correctness of the pinout; as practice shows, in 90% of cases the reason lies precisely in this.

When using a shielded cable, you must install an appropriate socket that has a shield connection. Otherwise, it turns into a large antenna, which will immediately affect the bandwidth, and, consequently, the data transfer speed. For the same reason, you should not use an STP or FTP cable if ungrounded equipment is connected to it.

Twisted pair LAN technology requires the use of continuous lines. Twists and adhesions are unacceptable; this leads to serious losses. If it becomes necessary to extend a piece of cable, special connectors should be used for this purpose.


Rice. 12. Twisted pair connectors

These devices are a box in which a board is installed with two RJ-45 connectors (A in Fig. 12), or twisted pair clamps, like sockets (B in Fig. 12).

Not recommended in living conditions use sockets with more than two ports. A large number of patch cords in one place will cause them to become tangled. It is better to space the sockets some distance apart.

Loading...